深圳飛宇光纖系統有限公司
1光性能/Optical Specification (平頂AWG/ FlattopThermalAWG)
參數/Parameters條件/Condition規格/Specs單位/Units
MinTypMax
1 光性能/Optical Specification (平頂AWG/ FlattopThermalAWG)
參數/Parameters | 條件/Condition | 規格/Specs | 單位/Units | ||||
Min | Typ | Max | |||||
通道數/Number of Channels |
| 40 |
| ||||
通道間距/Number Channel Spacing | 100GHz | 100 | GHz | ||||
中心波長/Cha. Center Wavelength | ITU頻率/ITU frequency. | C -band | nm | ||||
通帶頻率/Clear Channel Passband |
| ±0.1 | nm | ||||
波長精度/Wavelength Stability | Maximum range of the wavelength error of all channels and temperatures in average polarization. | ±0.05 | nm | ||||
-1 dB帶寬/-1 dB Channel Bandwidth | Clear channel bandwidth defined by passband shape. For each channel | 0.4 |
|
| nm | ||
-3 dB帶寬/-3 dB Channel Bandwidth | Clear channel bandwidth defined by passband shape. For each channel | 0.6 |
|
| nm | ||
插損/Optical Insertion Loss at ITU grid | Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations. |
| 4.5 | 6.0 | dB | ||
相鄰通道隔離度/Adjacent Channel Isolation | Insertion loss difference from the mean transmission at the ITU grid wavelength to thehighest power, all polarizations, within the ITU band of the adjacent channels. | 25 |
|
| dB | ||
非相鄰通道隔離度/Non-Adjacent, Channel Isolation | Insertion loss difference from the mean transmission at the ITU grid wavelength to thehighest power, all polarizations, within the ITU band of the nonadjacent channels. | 30 |
|
| dB | ||
總隔離度/Total Channel Isolation | Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of all other channels, including adjacent channels. | 22 |
|
| dB | ||
插損*性/Insertion Loss Uniformity | Maximum range of the insertion loss variation within ITU across all channels, polarizations and temperatures. |
| 1.0 | 1.5 | dB | ||
方向性Directivity(Mux Only) | Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n | 40 |
|
| dB | ||
插損平坦度/Insertion Loss Ripple | Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port |
|
| 0.5 | dB | ||
回損/Optical Return loss | Input & output ports | 40 |
|
| dB | ||
PDL/Polarization Dependent Loss in Clear Channel Band | Worst-case value measured in ITU band |
| 0.3 | 0.5 | dB | ||
偏振模式色散/Polarization Mode Dispersion |
|
|
| 0.5 | ps | ||
zui大承受光功率/Maximum Optical Power |
|
|
| 23 | dBm | ||
功率監控范圍/MUX/DEMUX input/ output Monitoring range |
| -35 |
| +23 | dBm | ||
|
|
|
|
|
|
|
|
2 IL Represents the worst case over a +/-0.1nm window around the ITU wavelength.
3 PDL was measured on average polarization over a +/- 0.1nm window around the ITU wavelength.