好爽又高潮了毛片免费下载,国产97在线 | 亚洲,亚洲一区二区三区AV无码,特级AAAAAAAAA毛片免费视频

行業產品

  • 行業產品

深圳飛宇光纖系統有限公司


當前位置:深圳飛宇光纖系統有限公司>>C/DWDM波分傳輸>>40 CH AWG 波分復用器

40 CH AWG 波分復用器

返回列表頁
參  考  價面議
具體成交價以合同協議為準

產品型號

品       牌

廠商性質生產商

所  在  地深圳市

聯系方式:陳順意查看聯系方式

更新時間:2018-05-14 09:00:00瀏覽次數:738次

聯系我時,請告知來自 智慧城市網

經營模式:生產廠家

商鋪產品:4條

所在地區:廣東深圳市

聯系人:陳順意 (銷售)

產品簡介

1光性能/Optical Specification (平頂AWG/ FlattopThermalAWG)
參數/Parameters條件/Condition規格/Specs單位/Units
MinTypMax

詳細介紹

1         光性能/Optical Specification (平頂AWG/ FlattopThermalAWG)

參數/Parameters

條件/Condition

規格/Specs

單位/Units

Min

Typ

Max

通道數/Number of Channels

 

40

 

通道間距/Number Channel Spacing

100GHz

100

GHz

中心波長/Cha. Center Wavelength

ITU頻率/ITU frequency.

C -band

nm

通帶頻率/Clear Channel Passband

 

±0.1

nm

波長精度/Wavelength Stability

Maximum range of the wavelength error of all channels and temperatures in average polarization.

±0.05

nm

-1 dB帶寬/-1 dB Channel Bandwidth

Clear channel bandwidth defined by passband shape. For each channel

0.4

 

 

nm

-3 dB帶寬/-3 dB Channel Bandwidth

Clear channel bandwidth defined by passband shape. For each channel

0.6

 

 

nm

插損/Optical Insertion Loss at ITU grid

Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations.

 

4.5

6.0

dB

相鄰通道隔離度/Adjacent Channel Isolation

Insertion loss difference from the mean transmission at the ITU grid wavelength to thehighest power, all polarizations, within the ITU band of the adjacent channels.

25

 

 

dB

非相鄰通道隔離度/Non-Adjacent, Channel Isolation

Insertion loss difference from the mean transmission at the ITU grid wavelength to thehighest power, all polarizations, within the ITU band of the nonadjacent channels.

30

 

 

dB

總隔離度/Total Channel Isolation

Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of all other channels, including adjacent channels.

22

 

 

dB

插損*性/Insertion Loss Uniformity

Maximum range of the insertion loss variation within ITU across all channels, polarizations and temperatures.

 

1.0

1.5

dB

方向性Directivity(Mux Only)

Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n

40

 

 

dB

插損平坦度/Insertion Loss Ripple

Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port

 

 

0.5

dB

回損/Optical Return loss

Input & output ports

40

 

 

dB

PDL/Polarization Dependent Loss in Clear Channel Band

Worst-case value measured in ITU band

 

0.3

0.5

dB

偏振模式色散/Polarization Mode Dispersion

 

 

 

0.5

ps

zui大承受光功率/Maximum Optical Power

 

 

 

23

dBm

功率監控范圍/MUX/DEMUX input/ output

Monitoring range

 

-35

 

+23

dBm

 

 

 

 

 

 

 

 

2         IL Represents the worst case over a +/-0.1nm window around the ITU wavelength.

3         PDL was measured on average polarization over a +/- 0.1nm window around the ITU wavelength.

 


感興趣的產品PRODUCTS YOU ARE INTERESTED IN

智慧城市網 設計制作,未經允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.cmr6829.com,All rights reserved.

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,智慧城市網對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~