通信電纜 網絡設備 無線通信 云計算|大數據 顯示設備 存儲設備 網絡輔助設備 信號傳輸處理 多媒體設備 廣播系統 智慧城市管理系統 其它智慧基建產品
山東恒兆信息科技有限公司
FEATURES l Compliant with 40G Ethernet IEEE802.3ba and 40GBASE-LR4 Standard l QSFP+ MSA compliant l Compliant with QDR/DDR Infiniband data rates l Up to 11.2Gb/s data rate per wavelength l 4 CWDM lanes MUX/DEMUX design l Up to 10km transmission on single
FEATURES
l Compliant with 40G Ethernet IEEE802.3ba and 40GBASE-LR4 Standard
lQSFP+ MSA compliant
lCompliant with QDR/DDR Infiniband data rates
lUp to 11.2Gb/s data rate per wavelength
l4 CWDM lanes MUX/DEMUX design
lUp to 10km transmission on single mode fiber (SMF)
lOperating case temperature: 0 to 70 ℃
lMaximum power consumption 3.5W
lLC duplex connector
lRoHS compliant
APPLICATIONS
l40GBASE-LR4 Ethernet Links
lInfiniband QDR and DDR interconnects
lClient-side 40G Telecom connections
Mechanical Dimensions
Optical Characteristics
Parameter | Symbol | Min | Typical | Max | Units | Notes | ||
Wavelength Assignment | L0 | 1264.5 | 1271 | 1277.5 | nm | |||
L1 | 1284.5 | 1291 | 1297.5 | nm | ||||
L2 | 1304.5 | 1311 | 1317.5 | nm | ||||
L3 | 1324.5 | 1331 | 1337.5 | nm | ||||
Transmitter | ||||||||
Side Mode Suppression Ratio | SMSR | 30 | dB | |||||
Total Average Launch Power | PT | 8.3 | dBm | |||||
Average Launch Power, each Lane | PAVG | -7 | 2.3 | dBm | ||||
Optical Modulation Amplitude (OMA), each Lane | POMA | -4 | 3.5 | dBm | 1 | |||
Difference in Launch Power between any Two Lanes (OMA) | Ptx,diff | 6.5 | dB | |||||
Launch Power in OMA minus Transmitter and Dispersion Penalty (TDP), each Lane | -4.8 | dBm | ||||||
TDP, each Lane | TDP | 2.6 | dB | |||||
Extinction Ratio | ER | 3.5 | dB | |||||
Relative Intensity Noise | RIN | -128 | dB/Hz | 12dB reflection | ||||
Optical Return Loss Tolerance | TOL | 20 | dB | |||||
Transmitter Reflectance | RT | -12 | dB | |||||
Transmitter Eye Mask Definition {X1, X2, X3, Y1, Y2, Y3} | {0.25,0.4,0.45,0.25,0.28,0.4} | |||||||
Average Launch Power OFF Transmitter, each Lane | Poff | -30 | dBm | |||||
Receiver | ||||||||
Damage Threshold, each Lane | THd | 3.3 | dBm | 2 | ||||
Total Average Receive Power | 8.3 | dBm | ||||||
Average Receive Power, each Lane | -13.7 | 2.3 | dBm | |||||
Receiver Reflectance | RR | -26 | dB | |||||
Receive Power (OMA), each Lane | 3.5 | dBm | ||||||
Receiver Sensitivity (OMA), each Lane | SEN | -11.5 | dBm | |||||
Stressed Receiver Sensitivity (OMA), each Lane | -9.6 | dBm | 3 | |||||
Difference in Receive Power between any Two Lanes (OMA) | Prx,diff | 7.5 | dB | |||||
LOS Assert | LOSA | -28 | dBm | |||||
LOS Deassert | LOSD | -15 | dBm | |||||
LOS Hysteresis | LOSH | 0.5 | dB | |||||
Receiver Electrical 3 dB upper Cutoff Frequency, each Lane | Fc | 12.3 | GHz | |||||
Conditions of Stress Receiver Sensitivity Test (Note 4) | ||||||||
Vertical Eye Closure Penalty, each Lane | 1.9 | dB | ||||||
Stressed Eye J2 Jitter, each Lane | 0.3 | UI | ||||||
Stressed Eye J9 Jitter, each Lane | 0.47 | UI |