好爽又高潮了毛片免费下载,国产97在线 | 亚洲,亚洲一区二区三区AV无码,特级AAAAAAAAA毛片免费视频

行業產品

  • 行業產品

深圳市金源光電通訊技術有限公司


當前位置:深圳市金源光電通訊技術有限公司>>高清矩陣>>HDMI 8*8矩陣

HDMI 8*8矩陣

返回列表頁
參  考  價面議
具體成交價以合同協議為準

產品型號

品       牌

廠商性質生產商

所  在  地深圳市

聯系方式:王明查看聯系方式

更新時間:2022-06-22 17:16:38瀏覽次數:259次

聯系我時,請告知來自 智慧城市網

經營模式:生產廠家

商鋪產品:54條

所在地區:廣東深圳市

聯系人:王明 (銷售經理)

產品簡介

IntroductionHDMX0008M1isan8-by-8HDMImatrix

詳細介紹

Introduction
HDMX0008M1 is an 8-by-8 HDMI matrix. It allows any of the eight Input Channels (HDMI) to be routed to any of the eight Output Channels (HDMI), no matter the source is HDCP or not. Users can choose several different ways to control the matrix: by using infrared, RS232, and LAN and supplied remote control.
 
HDMX0008M1 internal EDID library features default EDID configurations, in addition to native EDID data for any output/display.
 
HDMX0008M1 offers solutions for digital entertainment center, HDTV retail and show site, HDTV, STB, DVD and projector factory, noise, space and security concerns, data center control, information distribution, conference room presentation, school and corporate training environments.
 
 
■ Features
l Allows up to eight HDMI audio/video devices to be independently switched to eight HDMI monitors, HDTV’s, or projectors.
l The eight output channels could show the same or different source simultaneously no matter the source is HDCP or not.
l Reading and saving EDID function from displays.
l Support high definition resolutions, including:
1080p@60Hz@36 b/pixels, 3D, 1080i, 720p and other standard video formats.
l Each port support both HDMI and DVI inputs.
l With extra infrared extension receiver.
l Four switching modes: panel buttons, local IR, RS232 and Ethernet.
l HDCP compliant
l HDMI 1.3 supported.
 
■ Package Contents
①       1x Main unit. P/N_ HDMX0008M1.
②       1x Remote.
③       1x IR RX (IR receiver cable).
④       1x RS232 converter.
⑤       12V/DC Power Supply. P/N_VDC01205.
⑥       Operating Instructions. P/N_INS HDMX0008M1.
⑦       Mounting ears.
& NOTE: PART NUMBER (Abbreviation as P/N).
 

■ Panel Descriptions
①      LCD indicator, displays the status of each output port.
②      IR receive window.
③      OUT1~8 & IN1~8: Press the output source selection button in order to choose which input port corresponds to the desired output port. First select your output port form 1~8, then choose the desired input port from ports 1~8.
④      ALL: Press this button to set all the outputs to display with the same input. First press the “ALL” button then press an input number to confirm the selection.
⑤      LOCK: Press this button to lock all the functions and press it again to release the lock.
 
①      RS232 port.
②      LAN port.
③      HDMI output port.
④      HDMI input port (HDMI or DVI).
⑤      Power: Press this button to turn the system on.
⑥      IR extender: This slot is where you can extend your IR receiver with an IR extender cable that supports only 38KHz.
⑦      Power input: Plug the 12V DC power supply into the unit and connect the adaptor to an AC wall outlet.
 
■ Connections and Operations
 
1)     Connect the HDMI input source (such as HD-DVD/ PS3/STB etc.)Into HDMX0008M1.
2)     Connect HDMI OUT of HDMX0008M1 to display equipment.
3)     Connect the Broadband IR receive cable into HDMX0008M1 IR RX ports.
4)     Power on the input source you want to show. (Keep the unused input power off, otherwise it may interfere the normal display).
5)      Plug the power cable into HDMX0008M1.
6)       Turn on the power, when the LED panel stops flashing circularly, the initialization of the matrix are ready.
7)       Turn on the displays you want to watch.
8)       Use the remote to control the matrix, or using Front Panel, RS232 and LAN port to control.
2. Control via IR remote.
 
 
User can control the HDMI route of the matrix by using the IR remote. There are two group key pads for sixteen ports. Press the output source selection button in order to choose which input port corresponds to the desired output port. (For example: Output 8 select Input 7, first press output 8, then press input 7, LCD display 8-7)
 
 
NOTE:if the IR remote isn’t work, please press the”system code switch key”, but please do not put the remote against theXZ0808-001
  
 
3. Control via RS232.
 
 
 
1)The Interface of HDMX0008M1 comctl

2)The Message Window
 
2.1) Receive Window

The “receive window” will show the message received from MX0808. When you click the Control Buttons (see step 4) or send Control Command (see 2.3) to MX0808, it will send out the message about “operation results” as below:
2.2) Status Button
Click this button to read the status of MX0808. The status is about which input is selected by the output.
 
2.3) Send Window

Input the control command in this window. The control command use ASCII.
 
2.4)Setting Button
Click this button to enter Setting menu. 
2.5)IP SET Button
Click this button to set IP address for LAN control (for example: 192.168.0.3).
 
 
2.7)     EDID Set button
Select the Output Port in “Port Select” column, click “Read” button to get EDID from display equipment.
 
Select the Input Port in “Port Select” column, click “Write” button to set EDID of this Input Port the same as display equipment.
 
Click “Save as” button to save EDID read from display equipment as “*.bin” file.
Click “Open” button to open saved “*.bin” file, select the Input Port in “Port Select” column, click “Download” button to set EDID of this Input Port the same as “*.bin” file.
 
 
 
 
3)The Com status
3.1)Connect state.
Connect state shows the com open or not.
 
3.2)Com select.
à Select which com you will use.
à Connect button.
The word on this button will change when the connection state changes. If the word is “Disconnect”, then click this button, the com will be closed. If the word is “Connect”, then click this button, the com will be opened.
 
4)Control command format
If user want to write his own control software, below are data format and baud rate setting.
Com port setting:
Baud Rate: 9600 bps
Data bits: 8 bits
Parity: None
Stop bits: 1 bit
Flow control: None
 
 
5) RS232 command
 
command HEX feedback description
cir_0x
63 69 72 20 30 xx 0D 0A s1y
Output 1 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
cir_1x
63 69 72 20 31 xx 0D 0A s2y
Output 2 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
cir_2x
63 69 72 20 32 xx 0D 0A s3y
Output 3 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
cir_3x
63 69 72 20 33 xx 0D 0A s4y
Output 4 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
cir_4x
63 69 72 20 34 xx 0D 0A s5y
Output 5 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
cir_5x
63 69 72 20 35 xx 0D 0A s6y
Output 6 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
cir_6x
63 69 72 20 36 xx 0D 0A s7y
Output 7 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
cir_7x
63 69 72 20 37 xx 0D 0A s8y
Output 8 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
asw_x
61 73 77 20 xx 0D 0A
s1y
s2y
s3y
s4y
s5y
s6y
s7y
s8y
All output select input x;
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
bc_
62 63 20 0D 0A
s1x
s2x
s3x
s4x
s5x
s6x
s7x
s8x
Obtain the input status.
“x” : indicate the input port, range from 1~8.
sed_x_y
73 65 64 20 xx 20 yy 0D 0A sed_x_y
Copy edid from “x” to “y”,
“x””y” range from 0~7
rst_
72 73 74 20 0D 0A   Reset factory settings.
 
6) Web password reset
The command length is 4 bytes.
rpw+ ‘↙’
“rpw” is the key word , ‘↙’ is carriage return.
When you send the Web password reset command to MX0808, if succeed, it will feedback "rpw", and the web password will be set as "0000000000".
 

 

4. LAN control
?   Note: Use the direct UTP cable to connect with PC, or use cross cable to connect to the Ethernet switcher
 
A.Double click Netfinder.exe. Click “Search” button to get the device IP address.
 
 
B.Click “Web Browser” button. A web browser will be shown. The default password is "0000000000", input the password and login. The device controller page will be displayed.
 
 
The right area is for device controlling. Click these buttons to control the device. It is the same as using the remote controller. The left area shows which input ports are being chosen by the output ports.
 
C.Telnet Control
Telnet matrix’s IP address
 
Now you can control the matrix (Page 14: Control command format)
 
 
■ Specifications
Operating Temperature Range 0 to +35°C (32 to +95°F)
Operating Humidity Range 5 to 90 % RH (no condensation)
Input Video Signal 0.5-1.0 volts p-p
Input DDC Signal 5 volts p-p (TTL)
Video Format Supported
DTV/HDTV:3D/ 1080P/1080i/720P/
576P/480P/576i/480i
Audio Format Supported DTS-HD、Dolby HD
Output Video HDMI 1.3 with 3D
Maximum Transmission Distance 1080P 15m over HDMI cable
Power Consumption 24 Watts (Max.)
Dimensions W436.9XH211XT44.5mm
Mass (Main unit) 2800g
 
& NOTE: Specifications are subject to change without notice. Mass and dimensions are approximate.
■Typical Application
 
■ Maintenance
Clean this unit with a soft, dry cloth.Never use alcohol, paint thinner or benzine to clean this unit.
 
 ■ Product Service
● Provided Service
1)       Damage Requiring service: The unit should be serviced by qualified service personnel if:
l The DC power supply cord or AC adaptor has been damaged;
l Objects or liquids have gotten into the unit;
l The unit has been exposed to rain;
l The unit does not operate normally or exhibits a marked change in performance;
l The unit has been dropped or the cabinet damaged.
2)       Servicing Personnel: Do not attempt to service the unit beyond that described in these operating instructions. Refer all other servicing to authorized servicing personnel.
3)       Replacement parts:When parts need replacing ensure the service uses parts specified by the manufacturer or parts that have the same characteristics as the original parts. Unauthorized substitutes may result in fire, electric shock, or other hazards.
4)       Safety check:After repairs or service, ask the service to perform safety checks to confirm that the unit is in proper working condition.
 
●Mail-In Service
When shipping the unit, carefully pack and send it prepaid, adequately insured and preferably in the original carton. Include a letter detailing the complaint and provide a daytimephone and/or address where you can be reached.
If repair is needed during the limited warranty period the purchaser will be required to furnish a sales receipt/proof of purchase indicating date of purchase, amount paid and place of purchase. Customer will be charged for the repair of any unit received without such proof of purchase.
● Warranty
If your product does not work properly because of a defect in materials or workmanship, ASK Company (referred to as “the warrantor”) will, for the length of the period indicated as below, (Parts (1) Year, Labor(90) Days)which starts with the date of original purchase (“Limited Warranty period”), at its option either (a) repair your product with new or refurbished parts, or (b) replace it with a new or a refurbished product. The decision to repair or replace will be made by the warrantor.
During the “Labor” Limited Warranty period there will be no charge for labor. During the “Parts” warranty period, there will be no charge for parts. You must mail-in your product during the warranty period. This Limited Warranty is extended only to the original purchaser and only covers product purchased as new. A purchase receipt or other proof of original purchase date is required for Limited Warranty service.
 
● Warranty Limits And Exclusions
1)       This Limited Warranty ONLY COVERS failures due to defects in materials or workmanship, and DOES NOT COVER normal wear and tear or cosmetic damage. The Limited Warranty ALSO DOES NOT COVER damages which occurred in shipment, or failures which are caused by products not supplied by the warrantor, or failures which result from accidents, misuse, abuse, neglect, mishandling, misapplication, alteration, faulty installation, set-up adjustments, maladjustment of consumer controls, improper maintenance, power line surge, lightning damage, modification, or service by anyone other than a Factory Service Center or other Authorized Service, or damage that is attributable to acts of God.
2)       There are no express warranties except as listed under “limited warranty coverage”. The warrantor is not liable for incidental or consequential damages resulting from the use of this product, or arising out of any breach of this warranty.(As examples, this excludes damages for lost time, cost of having someone remove or re-install an installed unit if applicable, travel to and from the service location, loss of or damage to media or images, data or other recorded content. The items listed are not exclusive, but are for illustration only.)
 
 


感興趣的產品PRODUCTS YOU ARE INTERESTED IN

黃金視訊科技-數字化設備

GEV1024 數字矩陣 面議

黃金視訊科技-數字化設備

GEV1024M 多媒體矩陣 面議

矩陣控制器

VJZ-0848AV 面議

矩陣控制器

VJZ-0856AV 面議

矩陣控制器

VJZ-0864AV 面議

矩陣控制器

VJZ-0840AV 面議

8進4出AV音視頻矩陣切換器,八進四出AV矩陣

AV矩陣8進4出,八進四出音視頻矩陣,AV0804 面議

黃金視訊科技-數字化設備

GEV1394硬盤陣列柜 面議

智慧城市網 設計制作,未經允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.cmr6829.com,All rights reserved.

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,智慧城市網對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~